Stoebich Flexible Smoke Curtains
Specialized separation technologies
Smoke Curtain S
Automatic sectional flexible smoke curtains (UL 12784)
System Description
- For high time class and temperature loads D120 (1,112 °F)
- Without residual openings – neither in the upper area nor in the corners
- No support necessary, despite this absolutely tight even under pressure loads
- Low installation height of the casing of approx. 4,92″ at an AL < 118.11″
- As standard with the ‘Gravigen’ drive system, i.e. closes without any external energy
- Fire-resistant cables are not necessary
- Redundant drive systems as a fall guard
- Suitable (approved) also as a floor-closing smoke protection curtain
Smoke Curtain H
Automatic horizontal flexible smoke curtains (UL 1784)
System description
- System for large openings in ceilings without supporting or tensioning cables up to 33′ x 33′ (two-part version up to 33′ x 66′)
- Housing and bottom bar build a closed casing under operating condition
- Motorized closing and opening (emergency power supply is required)
Smoke Curtain HC
Automatic horizontal flexible smoke curtains (UL 1784)
System description
- System for large openings in ceilings up to 66′ in width and high drop length
- Tensioning cables in a distance of 5′ to support the fabric with large dimensions as well as for the pressure load in case of smoke
- High variability in design (e.g. arch-shape)
- Safe-closing process up to 17′ drop length with gas spring (no auxiliary energy) or with duplex drive system (electrical power supply is required) for drop length up to 30′
- Spring system is closing with fail-safe technology
Smoke Curtain P
Automatic vertical flexible smoke curtains for large dimensions and highest demands (UL 1784)
System Description
- Automatic smoke protection with a high temperature classification
- 0% leakage with side guides
- One-part with a system width up to 160′ and a large drop length up to 30′
- High variability in construction and design
- No opening remaining within the housing area
- Drive unit with fail-safe technology (closing without auxiliary power)
- Drive unit with 10,000 cycles
- Self-leveling bottom bar, safety edge (optional)
- Egress door for smoke curtains, closing down to the floor (optional)
- Suitable as smoke curtain that is flush with the floor
Smoke Curtain X
System Description
- Automatic smoke protection with a high temperature classification
- Creation of smoke compartments in alleyways respectively in escape routes with a passage for people (200 persons per minute at a system width of 10′ is possible)
- Double-coil system (unlimited system width possible, drop length up to 12′)
- Low installation height
- Drive unit with fail-safe technology (closing without auxiliary power)
- Drive unit with 10,000 cycles
- Soft, elastic and interrupted bottom bar to avoid any injuries
- Translucent fabric (optimized visibility in the area of the passage)
Smoke Curtain C
System Description
- Automatic smoke protection with a high temperature classification
- System width up to 1,000′ and drop length up to 13′
- Closed, curved design for installation in circle – or elli
- No overlapping and remaining openings (connected module)
- Fabric and housing integrated in the suspended ceilings
- drive unit with fail-safe technology (closing without auxiliary power)
- Drive unit with 10,000 cycles
- Lightning integrable (optional)
Smoke Curtain M
System Description
- Automatic smoke protection with a high temperature classification
- Pre-manufactured single elements to create one complete unit (modular installation)
- Unlimited system width possible, drop length up to 23′
- Connected bottom bar across all elements
- Alternatively with side guides
- Drive unit with fail-safe technology (closing without auxiliary power)
- Drive unit with 10,000 cycles
- Suitable as smoke curtain that is flush with the floor
- Self-leveling bottom bar, safety edge (optional)
Draft Curtain
- Fixed smoke protection with a high temperature classification
- Large dimensions are possible (unlimited system widths, height depends on the wind pressure which may occur)
- Pending fixing or fixing at the lateral and lower area
- Extremely small static load to the building structure (weight of the fabric: 0.08 – 0.14 lbs/ft2)
- Fabric tested according to ASTM E84
- Easy sealing of systems which pass through the fixed barrier (e.g. ventilation ducts, tubes, cable routes, I-beams)
- Number of systems which pass through the fixed barrier is expandable or changeable during the whole life of installation.
Smoke Curtain T
System Description
- Automatic tight smoke protection with a high temperature classification
- System width up to 33′ and a drop length up to 20′
- Passive sealing system with noncombustible sealing parts
- Elastic floor sealing to seal bigger uneveness
- Versatile mounting options
- Drive unit with fail-safe technology (closing without auxiliary power)
- Drive unit with 10,000 cycles
- High quality fabric with silicone coating or with polyurethane coating
- Safety edge (optional)
Stoebich Smoke Curtains
Stoebich Fire Protection – the world leader* has already developed and established in the market 11 world novelties. Over 35 years, Stoebich successfully completed more than 60 fire tests alone for conveyor system closures in many countries.
Additional Assistance